GREASTER The Greaster incorporates both a resettable batch total displayed in ounces, and a non-resettable cumulative total displayed in pounds. Why use a grease meter? Under normal operating conditions the amount of grease dispensed is highly variable due to various factors such as pump size, efficiency, plumbing diameter and length, type of grease, ambient temperature and line restrictions to name just a few. With the Greaster Meter you can now be assured of the amount of grease that is actually dispensed, regardless of the system operating conditions. Body: Machined
aluminum body, handle and gear cover. Steel control lever handle contains
receptacle for two Inlet: 1/4 NPTF Outlet: 1/8 NPTF Meter: Oval
gear sensing elements, easily accessed via front cover held in place
by 4 ea. 3 mm Electronics:
Microprocessor controlled with LCD display. Batch total (resettable),
cumulative total Control Lever Lock: Allows discharge lever to be safely secured to prevent accidental opening of the discharge valve.
|
|
| Performance
Specifications: Operating Pressure (max.) Burst Pressure (min.) Metering Accuracy Display Battery Type/Life Weight Operating Temperature Range |
7,250 PSI 14,500 PSI +/- 3% Batch Total (oz.), 4 digits, 0.31 digit height Cumulative Total (lb.), 4 digits, 0.16 digit height) 2 ea. AA / 10,000 hrs. 2.16 lb. (batteries included) 30° F to 140° F |
|
Popular Models Available: P/N 100450
Model LG-100, Grease Meter Only (oz./lb. display) Note: Other models available upon request |
|